Gasket Tedex blue
TEDEX HIGH-PERFORMANCE GASKET BLUE
GASKET TEDEX BLUE
![]() basis, filled with tubular micro glass beads. Colour: blue Application Because of the chemical resistance it is ideal for all chemicals in the ph range of 0-14. Exceptions: Hydrogen fluorides, fluorine compounds, melting of alkaline metals. Complies with the FDA-, KTW- and WRC regulations, hence explicitly appropriate for enamelled flanges and gauge glasses. | Operating Data![]() These data are guide values which are based on the standard thickness of 2.0 mm and may not occur simultaneously. The values are to be modified depending on the thickness.Technical Data ![]() Standard sheet 1,500 x 1,500 mm Thickness 0.75 mm up tp 3.2 mm |
Gasket Tedex red
![]() Colour: light red Application Because of the chemical resistance it is ideal for all chemicals in the ph range of 0-14. Exceptions: Hydrogen fluorides, fluorine compounds, melting of alkaline metals. Complies with the FDA-, KTW- and WRC regulations, hence explicitly appropriate for the food and pharmaceutical industries. | Operating Data![]() ![]() Standard sheet 1,500 x 1,500 mm Thickness 0.75 mm up to 3.2 mm |
Gasket Tedex white
TEDEX HIGH-PERFORMANCE ASKET WHITE
![]() Colour: white/pigment free Application Because of the chemical resistance it is ideal for all chemicals in the ph range of 0-14. Exception: Hydrogen fluorides, fluorine compounds, melting of alkaline metals. Complies with the FDA-, KTW- and WRC regulations, hence explicitly appropriate for the food and pharmaceutical industries. | Operating Data![]() These data are guide values which are based on the standard thickness of 2.0 mm and may not occur simultaneously. The values are to be modified depending on the thickness.Technical Data ![]() Standard sheet 1,500 x 1,500 mm Thickness 0.75 mm up to 3.2 mm |
Tedex soft/white
TEDEX HIGH-PERFORMANCE GASKET SOFT/WHITE
GASKET TEDEX SOFT/WHITE
![]() Colour: white/pigment free Application Because of the chemical resistance it is ideal for flanges of glass and enamel. Complies with the FDA-, KTW- and WRC regulations, hence explicitly appropriate for the food and pharmaceutical industries. | Operating Data![]() standard thickness of 2.0 mm and may not occur simultaneously. The values are to be modified depending on the thickness.Technical Data ![]() Standard sheet 1,500 x 1,500 mm Thickness 0.75 mm up to 3.2 mm |
TediFlex Gasket
![]() | Do benefit from cold flow qualities of 100% pure PTFE with uneven or damaged seal surfaces! Tests and Approvals: • TÜV Test-No. MP 4/0051 • BAM Tgb.-No. 6228/89 4-2346 • DVGW Reg.-No. G88e089 Tested Values: • T: -240 up to +280°C • P: 300 bar • pH: 0 up to 14 |

Dimensions

Important installation note:
1. The seal surface must be clean, free from grease and dry. 2. Pull off cover, affix the sealing whereas starting at the bolt hole and overlap the ends at the bolt. | 3. Gradually pull the screws crosswise. 4. If necessary, adjust screws when operating temperature has been reached. |